Corrosion management: from monitoring points to decisions
Back to Knowledge Base
Asset Integrity 6 minKnowledge Base

Corrosion management: from monitoring points to decisions

2026-11-15

Corrosion data is only useful if it is taken in the right places and turned into action. A management loop links threats, monitoring, inspection and mitigation.

The situation

Corrosion management identifies damage mechanisms (CO2, H2S, oxygen, MIC, erosion-corrosion), selects materials and mitigation (inhibition, coatings, cathodic protection) and monitors effectiveness with probes, coupons and inspection.

Threats first

Start with what can corrode, why and where: internal corrosion from water, CO₂ and H₂S; microbial corrosion in stagnant areas; external corrosion under insulation or at soil interfaces; erosion where velocities are high. Group systems into corrosion circuits with similar conditions.

Diagram: Corrosion management
Figure: Atticus Energy, generic illustration.

Choosing monitoring locations

Place monitoring where damage is most likely, not where access is easiest:

  • Low points and dead legs where water collects.
  • Downstream of injection points and mixing tees.
  • Tank bottoms and the first shell course, where water and sediment settle.
  • Vapour spaces in tanks where condensation occurs.
  • Areas of high velocity or turbulence.

Monitoring tools

Corrosion coupons and probes show rates; ultrasonic thickness points show remaining wall; water chemistry and inhibitor residuals show whether controls are working.

Turning data into decisions

Compare measured rates with the remaining corrosion allowance and the planned life. Where rates rise, act early: adjust chemical dosing, increase inspection, plan repair or replacement.

Keep the loop closed

A corrosion management plan should be reviewed regularly, with operations, chemicals and integrity teams in the same room.

Key Takeaways

  • Define corrosion circuits by threat and condition.
  • Put monitoring where water and turbulence are.
  • Compare rates to remaining allowance and planned life.
  • Review the plan jointly with operations and chemicals teams.

How Atticus helps

We develop corrosion management plans, select monitoring locations for vessels, piping and tanks, and review integrity data to support life-extension decisions.

Real-world examples

Documented incident

Philadelphia Energy Solutions refinery — CSB (2019)

At the PES refinery a corroded pipe elbow in an HF alkylation unit ruptured, releasing process fluid that ignited and caused explosions. The CSB highlighted corrosion of a component with lower-than-expected corrosion resistance.

Read the investigation / source
Documented incident

Prudhoe Bay pipeline leak (2006)

Internal corrosion in an oil transit line led to a significant spill. Cleaning pigs had not been run for years, so sediment accumulated and corrosion progressed unseen.

Read the investigation / source

If you get it wrong

  • Loss of containment and fire or toxic release.
  • Unplanned shutdowns and costly repairs.
  • Environmental damage and regulatory action.
  • Shortened asset life.

Relevant standards

Links go to the publisher's official page (ISO, IEC, BSI, API, NFPA, HSE and others). Most standards must be bought from the publisher.

Further reading

Take this briefing with you